Home > Equipment > Spot Guns >

Albatross Expert Quick Dry 3500 Spot Cleaning Gun
Albatross Expert Quick Dry 3500 Spot Cleaning Gun


 
Ships from Los Angeles, CA OR Long Island, NY Please allow up to a 4 week lead time for this item to be manufactured.

free shipping FREE SHIPPING within the contiguous US!

Price:$259.99


Dropship Item
SKU: ALB-EXP-QD-3500
Qty:

Description Product Downloads
 

Albatross Expert Quick Dry 3500 Spot Gun

This innovative and heavy-duty spot cleaning gun combines the features of the Expert 3000 PSI Cleaning Gun with the addition of a built-in quick dry air nozzle. This added feature allows the user to clean and dry spots instantly. These advanced spot guns are perfect for high-volume screen printing operations, or smaller shops looking to invest in a spot cleaning solution that will last a long time.

CAUTION: The gun builds up considerable pressure. Never point the gun at yourself or other persons as this may cause injury. Spot Removal Gun is preset at the factory and adjustments are generally not required.

Instructions

  • Remove the container, fill with fluid (about 2/3 full) and replace. Plug into 110V 60 Hz outlet. Depress switch for 15-20 seconds to prime pump. Spray fluid onto scrap fabric to remove oil film from internal pump parts. Spray gun is now ready for use.
  • Adjustable Nozzle controls the pressure of the cleaning fluid. This is adjusted by simply rotating the nozzle collar on the front of the gun.
  • Volume Control Knob at the rear of gun controls the amount of fluid being dispensed. For cleaning, turn button as far left as possible: then back to right 1/2 to one revolution. Once adjustments are made to suit your needs, it is generally not necessary to change them.

Troubleshooting

Fluid Leakage It is necessary that all parts , particularly the nozzle head, be tight to prevent fluid working its way through the screw threads. Cleaning should be done at an angle no greater than 45° to prevent leakage from the air hole at the top of the gun. Leakage will also occur at the screw threads of the container cup if it is tilted forward for an extended period of time.

Lack of Pressure The primary cause of lack of pressure occurs when the suction tube, set screw, and nozzle head are not tight and the unit is sucking air. Blockage in the pump unit or nozzle and weak/damaged springs in the pump assembly are also a cause of low pressure. A lack of pressure will also occur when the prime is lost due to excessive tilting of the gun. Operation without Fluid It is highly recommended that this unit not be operated empty since undue wear and strain is caused on all working parts. Continued use of an empty pump will cause breakage of parts and needless repairs.

Lubrication The gun should not be over-lubricated. One or two drops of light machine oil used daily is sufficient to keep the pump unit in working condition. For storage or discontinued use, it is recommended that a light machine oil be pumped through the gun in the same manner as cleaning fluids for a period of 2 to 3 seconds. For start-up, cleaning fluid should run through the unit prior to operation so that any oily films are pumped through the unit and flushed out.


Product Reviews

Be the first to write a review